Vertiv liebert GXT RT+ 1ph 2kVA rack/tower UPS GXTRT-2000IRT2UXL
A smart battery charger design and external battery cabinet compatibility means you’ll have peace of mind knowing that your critical load will be supported during a failure or interruption to main utility power. In addition to the extended runtime, network interface or serial connections enable remote access to the Liebert GXT RT+ UPS for power consumption monitoring and configuration of alert notification parameters, further ensuring maximum value for best-in-class
power protection.
Key Benefits
- Broadcast and Entertainment
- Banking, Financial and Insurance
- Education
- Fire/Alarm/Security
- Government
- Healthcare
- Manufacturing
- Retail and Wholesale
- Telecom
- Transportation
Warranty: Standard 24-month product warranty
- Technical Data
- Product Overview
- Power Rating
- 2000VA / 1800W
- Input Voltage
- 230V AC Nominal (120-300V AC)
- Output Voltage
- 230V AC Default; 220/240VA User Selectable
- Efficiency
- Up to 89% (Normal mode, Full load)
- Wiring
- Input: IEC60320 C14 Output: 6 x IEC60320 C13
- Interfaces/Ports
- Interface Options
- USB, RS233, Slot for optional cards
- Control Panel
- LCD Display
- Operational Conditions
- Operating Temperature
- 0 – 40ºC
- Miscellaneous
- Listings
- CE, CB
- Topology
- On-line double conversion
Onsite Maintenance
1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VATNo matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included | Silver Level | Gold Level | Platinum Level |
|
| Technical Hotline 24/7 | Yes | Yes | Yes | |
| Preventative Maintenance | Yes | Yes | Yes | |
| Remote Monitoring 24/7 | Yes | Yes | Yes | |
| Firmware Upgrades | Yes | Yes | Yes | |
| Emergency Response | Yes | Yes | Yes | |
| Labour | Yes | Yes | Yes | |
| Parts | Yes | Yes | Yes | |
| Monthly Event/Status Report | option | option | option | |
| Onsite Crash Kit | option | option | option | |
| Response Time | 12 working hours | 8 working hours | 4 clock hours |
3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
| Engineer Installation and configuration during normal hours | |
| 24×7 flexible status and remote monitoring. | |
| Encrypted communication, allowing safe offsite monitoring | |
| Alarms and events emailed and SMS texted automatically | |
| Firewall Friendly | |
| Cloud based status overview and multiple sites status on one screen | |
| Allows First Fix Response to Site |
4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.