Mecer 2000VA 2KVA 1800W Tower UPS (ME-2000-WPTU)
Mecer 2000VA On-Line Tower UPS (ME-2000-WPTU) – Capacity: 2000VA / 1600W, Battery Type: 12V/9Ah, Frequency Range: 40Hz ~ 70 Hz, Includes AVR, Monitoring Software, Built-in Surge Protection, Black Colour Mecer ME-2000-WPTU 2KVA Online Smart UPS can charge up to 90% in battery capacity within a 4 hour period.
Overview
Provides reliable uninterruptible power supply (UPS) for sensitive electronics
Ideal for servers, workstations, network devices, and home office equipment
Capacity: 2000VA / 2KVA with 1800W power output
Line-interactive design for efficient voltage regulation
Automatically corrects minor power fluctuations without switching to battery
Helps conserve battery life and improves overall energy efficiency
Equipped with 4 x 12V 9AH batteries for extended backup time
Includes RS232 communication port for monitoring and management
Protects against power outages, surges, and voltage dips
Specifications
- Phase Single phase with ground
- Capacity 2000 VA / 1600 W
- Input Voltage Range Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5% (Ambient Temp. < 35°C) (based on load percentage 100% – 80% / 80% – 70% / 70-60 % / 60% – 0)
- Low Line Comeback 175 VAC / 155 VAC / 135 VAC / 125 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% – 80% / 80% – 70% / 70 60% / 60% – 0)
- High Line Transfer 300 VAC ± 5%
- High Line Comeback 290 VAC ± 5%
- Frequency Range 40HZ ~ 70 HZ
- Power Factor ? 0.99 @ nominal voltage
- Output Output Voltage 200/208/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode) ± 1%
- Frequency Range (Synchronised Range) 47 ~ 53 Hz or 57 ~ 63 Hz
- Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
- Current Crest Ratio 3:1 Harmonic Distortion ? 3 % THD (Linear Load), ? 6 % THD (non-linear load)
- Transfer Time AC Mode to Batt. Mode Zero
- Inverter to Bypass 4 ms (Typical)
- Waveform (Batt. Mode) Pure Sinewave
- Efficiency AC Mode 89%
- Battery Mode 87%
- Battery Battery Type 12 V 9 Ah
- Numbers 4 Typical Recharge Time 4 hours to recover to 90% capacity
- Charging Current (max.) 1.0 A
- Charging Voltage 54.7 VDC ± 1%
- Indicators LCD Panel UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
- Alarm Battery Mode Sounding every 4 seconds
- Low Battery Sounding every second
- Overload Sounding twice every second
- Fault Continuously sounding
- Physical Dimension, D x W x H (mm) 397 x 145 x 220
- Net Weight (kgs) 17
- Environment Humidity 20-90 % RH @ 0-40°C (non-condensing)
- Noise Level Less than 50dB @ 1 Meter
- Management Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
- Optional SNMP Power management from SNMP manager and web browser
Also Check:
Mecer 3000VA/2400W 3kva Smart Online UPS (ME-3000-WPTU)
Mecer 3000VA/2400W UPS ME-3000-WPTU